Page 21 - GRINNELL Mechanical Grooved Piping Products EMEA
P. 21

 Grooved Couplings
Figure 772 Rigid Couplings
Tech Data Sheet: G141
(Page 2 of 2)
        BC
BC
    B
C AAA
                            32mm - 300mm (11⁄4" - 12")
350mm - 450mm (14" - 18")
500mm - 600mm (20" - 24")
         Part Number
Pipe Size
Max.† Pres- sure Bar psi
Max.† End Load kN Lbs.
Max. *‡ End Gap mm In.
Dimensions
Approx. Weight Kg. Lbs.
                   Grade “E” Gasket
Grade “E” Tri-Seal Gasket
Nominal mm Inches
O.D. mm Inches
A mm In.
B mm In.
C mm In.
Qty.
Size
mm Inches
            772ME0324✖
772AE0355✖
772AE0406✖
772AE0457✖
772AE0508✖
772AE0610✖
772MT0324✖
772AE0355✖
772AE0406✖
772AE0457✖
772AE0508✖
772AE0610✖
12 12.750 400 14 14.000 350 16 16.000 350 18 18.000 350 20 20.000 350 24 24.000 350
51,071 0.13 53,878 0.13 70,372 0.13 89,064 0.25 109,956 0.25 158,336 0.25
15.41 16.68 18.50 21.31 23.50 27.63
18.84 2.62 2 20.38 2.93 3 22.64 2.93 3 25.12 3.06 3 27.88 3.06 4 32.00 3.19 4
1 x 61⁄2 • 42.0 1 x 51⁄2 • 48.0 1 x 51⁄2 • 52.1 1 x 51⁄2 • 68.0
11⁄8 x 53⁄4 • 89.0 11⁄8 x 53⁄4 • 96.0
300
323.9
27.6
227.17
3.3
391.4
478.5
66.5
M24 x 165
19.1
            350
  355.6
  24.1
  239.66
  3.3
  423.7
  517.6
  74.4
  –
  21.7
   400
  406.4
  24.1
  313.03
  3.3
  469.9
  575.1
  74.4
  –
  23.6
   450
  457.2
  24.1
  396.18
  6.4
  541.3
  638.0
  77.7
  –
  30.8
   500
  508.0
  24.1
  489.11
  6.4
  596.9
  708.2
  77.7
  –
  40.4
   600
  609.6
  24.1
  704.31
  6.4
  701.8
  812.8
  81.0
  –
  43.5
   ✖ = 1 for red paint finish, 2 for hot dipped galvanised finish
* Maximum available gap between pipe ends. Minimum gap = 0.
† Maximum Pressure and End Load are total from all loads based on standard weight steel pipe.
Pressure
ratings and end loads may differ for other pipe
materials and/or wall thicknesses. Contact a GRINNELL Sales Representative for details.
‡ Max End Gap is for cut grooved standard weight pipe. Values for roll grooved pipe will be half that of cut grooved.
• Only available in ANSI bolt sizes.
The Fig. 772 Heavy Duty Rigid Coupling does not provide compensation for pipe system expansion and/or contraction associated with pipe system
temperature changes.
For information on alternative sizes, contact a GRINNELL Sales Representative.
See page 17 for coupling specifications and pages 116 - 127 for gasket information.
For instructions on part numbers, ordering information, and availability, refer to page 13 or contact a GRINNELL Sales Representative.
Coupling Bolts
 21
   19   20   21   22   23